The Vibratron II provides a non-invasive means of measuring the sensitivity to vibration of a patient's hands and feet. Reliable quantitative measurements are achieved with a test that takes only minutes to administer. A two-alternative forced choice procedure is used to determine the degree of sensitivity. There are two ranges. For fine control, 0 - 6.5 vibration units corresponds to 0 - 20 microns. For low resolution, 6.5 - 19.9 vibration units corresponds to the 0 - 200 microns. A table and a formula are provided for conversion of vibration units to microns. Set up is accomplished in seconds and the equipment is easy to use. The system is therefore practical for both field studies and clinical testing. Possible environmental applications:
| |
| Controller | |
| Range -high resolution: -low resolution: | 6.5 - 19.9 vibration units (0 - 200 micron range) |
| Resolution: | |
| Display: | |
| Power Supply: | |
| Size: | 14.6 x 8.6 x 23.5 cm |
| Vibrators | |
| Size of base: | 12.7 x 7.6 x 10.2 cm |
| Post height: | |
| Accessories Supplied | |
| * Vibration units are converted to microns using the table or formula supplied in the operating manual. | |

Preset adjustment: 20-30°C and ± 20° either side of nominal set point in switchable 0.1° steps |
||
±0.1° ±1 digit |
||
200 - 240V AC 50 Hz 300W |
||
Safety shutdown with warning lamp in case of fault condition such as thermocouple sensor breakage, lack of cooling water or electronics failure. Self sealing sater connectors. |
||
| Auxilliary output for second controller | Auxilliary output for pump and tank unit | |
|
| The NTE2A Thermal
Probe is a sophisticated, non-invasive device for the clinical evaluation
of neuropathy and the assessment of short fiber neurological function. Individual
thresholds are compared to normals that can then be used to track nerve
function over time. It can also be used for pain studies and in any application
where a variable, accurately controlled temperature stimulus is required. The equipment comprises a hand held pen-shaped probe with a smooth flat tip 13mm in diameter on a 5 foot lead, a digitally set temperature control unit and a recirculating pump with a combined water reservoir, which is required to cool the probe during operation. The thermal probe, or thermode, utilizes a Peltier semiconductor heat pump to provide temperature stimuli above and below room temperature. The temperature range of the thermode extends from 0 to 50 degrees Centigrade and the response time to a step change in temperature is extremely fast , less than 4 seconds in the heating or cooling mode. The digital control unit incorporates proportional feedback to maintain accurate temperature control to within 0.1 degrees Centigrade. Setting of the control temperature is accomplished using three rotary switches providing switched steps of 5, 1 and 0.1 degrees covering a range of plus and minus 20 degrees about a base temperature that may be preset between 20 and 30 degrees Centigrade absolute. A digital display on the front panel indicates the temperature at the probe tip with a resolution of 0.1 degrees. An accessory D/A card and software program, the TPC-WIN Thermal Profile Controller, is available to provide the user with the ability to change the temperature of the probe under software control via a PC and create complex temperature profiles that can be recalled from file. The software will run under Windows '95 or 3.1. The equipment can be supplied for 110-120 or 200-240V AC operation. Please specify when ordering. |
| CONTROLLER SPECIFICATIONS | |
| OPERATING RANGE: | 20-30° C (Preset adjustment) and ±20.5° either side of nominal set point in switchable 0.1° steps. |
| CONTROL ACCURACY: |
|
| DIGITAL READOUT: | |
| Resolution |
|
| Accuracy |
|
| AMBIENT OPERATING RANGE |
|
| SET POINT |
|
| INPUT POWER REQUIREMENTS |
200 - 240V AC, 50Hz, 100W |
| SIZE |
|
| WEIGHT |
|
| OTHER FEATURES |
|
| THERMAL PROBE SPECIFICATIONS | |
| SIZE |
|
| WEIGHT |
|
| TEMPERATURE CONTROLLED SURFACE AREA |
|
| RANGE |
Note: Sustained exposure to temperatures over 46° C can cause burns. This equipment is not intended for use at temperatures over 45° C |
| RESPONSE TIME |
|
| OTHER FEATURES |
|