| TEMPERATURE DATA ACQUISITION - THERMES USB | |||||||||||||||||||||||||||||
• Turns any PC into a precision thermometer • 1 to 7 channels • ±0.1°C stability & clinical accuracy • 0.01°C Resolution • Reads up to 16 measurements per second • Input isolation for low leakage |
![]() |
||||||||||||||||||||||||||||
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accomodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes see our Temperature Probes section. |
|||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
| TEMPERATURE DATA ACQUISITION - THERMES WFi | |||||||||||||||
The THERMES USB WFI is a Type T Thermocouple data acquisition system with a secure 2.4GHz wireless link to its host computer. Specifications for the device are the same as the THERMES USB except for its wireless capability. The THERMES USB WFI includes a wireless receiver that is connected to the host computer via a USB port. All communications between the host computer and THERMES pass through this device. The THERMES USB WFI may be connected directly to the host computer via a standard USB port (from which it also draws its power) or operated remotely from the BP-1 battery pack. A wall mounting USB power supply is also provided with THERMES USB WFI. |
![]() |
||||||||||||||
OPT-1 Optical Link |
![]() 10 meter optically isolated interface with medical s grade power supply |
||||||||||||||
| Operating Software For customers who already have Labview or Dasylab no additional software is necessary. Recommended operating software is Dasylab Lite version 9.01. The Lite version provides all the necessary functions to display and store temperature data in digital and graphical formats in real time. Users may customize the display to suit their particular application. The Dasylab Basic version provides additional features for data manipulation and statistical analysis. |
|||||||||||||||
BP-1 Li-Ion Battery Pack The model BP-1 Li-Ion battery pack is designed for use with the THERMES USB and THERMES USB WFI Type T temperature data acquisition systems. It allows the data acquisition system to be operated for up to 100 hours continuously without any additional power source. The BP-1 provides either 16V, 19V or 5V DC output to run either the THERMES or a laptop for an extended period of time. The power supply has a capacity of 130 watt hours allowing the THERMES to operate for up to 100 hours continuously. Operating time with a laptop will vary from 3-4 hours in addition to the laptops fully charged normal running time. The BP-1 may also be used with our OPT-1, opto-isolator cable with the adaptor cable provided. A charge level indicator comprising four LEDs indicate remaining battery life. |
![]() External Li-ion battery pack powering Thermes Temperature Data Acquisition Systems |
||||||||||||||
|
|||||||||||||||
| TM-12 - Temperature Monitoring System for Hyperthermia | |||||||||||||||||||
![]() |
|
||||||||||||||||||
TheTM-12 thermocouple thermometry system will monitor temperature at up to eight sites. Sensor inputs are RF shielded, and data from the sensors is sent via RS232 interface to a computer. This combination of filtering and fast, accurate transmission of data is designed specifically for modern hyperthermia systems. The TM-12 can be used with microwave, RF and ultrasound since Physitemp has implantable microprobes suitable for all of these techniques. The TM-12 turns any IBM-compatible computer into a control center. You select the channels to be monitored and the update rate. Update rate can be as fast as eight channels per second or as slow as one cycle every 24 hours. Record keeping is automatic. Print and file facilities are activated by single keystrokes. Operating software is user-friendly and simple; set-up time is very short. Temperatures are displayed with a resolution of 0.01°C. Physitemp's clinical range of thermocouple probes are made with specially graded thermocouple wire and are accurate to 0.1° C in the physiological range. Input filters and shielding attenuate RFand microwave interference. A combination of fiber-optic links and high isolation AC-DC converters are used to isolate input circuitry. (INVESTIGATIONAL DEVICE: TO BE USED AT PHYSICIAN'S PROFESSIONAL DISCRETION) |
|
||||||||||||||||||